Clock Recovery Module for OI2125 O/E Receiver

OM1420

The products on this datasheet are no longer being sold by Tektronix.
View Tektronix Encore for reconditioned test equipment.
Check support and warranty status for these products.

Read Online:

Features & Benefits

  • Supports Multiple Data Rates up to 10.664 Gb/s: OC-192/STM-64 (9.953 Gb/s) and OC-192 FEC (10.664 Gb/s)
  • Increases Capability of the OI2125 O/E Receiver by Adding Clock Recovery
  • Easily Installed Modules

Applications

  • Bit Error Rate Testing
  • Optical Component and Fiber Loop Testing
  • Optical Transmitter Testing

High-performance OM1420 Module Adds Clock Recovery to the OI2125 O/E Receiver up to 10.664 Gb/s (OC-192/STM-64 FEC)

The Tektronix OI2125 O/E Receiver receives modulated optical signals up to 12.5 Gb/s and converts them to electrical signals for further testing with an instrument such as a BER (bit error rate) analyzer. The user-installable OM1420 OC-192 Dual-rate Clock Recovery Module extracts the clock for both OC-192 9.953 Gb/s and OC-192 FEC 10.664 Gb/s rates. The recovered clock signal can then be used to trigger a CSA8000 sampling oscilloscope or be used as the clock input to an error analyzer.

Characteristics

OM1420 OC-192/STM-64 Clock Recovery Module

Specification

Min

Typ

Max

Units

Comments

Clock Recover Data Rate

   

9.953280 10.66423

   

Gb/s Gb/s

Switchable

Jitter Generation

   

   

2

psRMS

   

Clock Bandwidth

   

   

10

MHz

   

Input Amplitude

0.15

   

0.75

Vp-p

   

Clock Output Amplitude

1.0

   

2.0

Vp-p

   

Environment

Temperature -

Operating: 0 °C to +40 °C.

Nonoperating: -40 °C to +71 °C.

 

Humidity -

Operating: 5% to 95% RH (up to +30 °C).

   5% to 45% RH (30 °C to +50 °C).

Nonoperating: 5% to 95% RH (up to +30 °C).

   5% to 45% RH (30 °C to +50 °C).

 

Altitude -

Operating: Up to 3000 m (10,000 ft.).

Nonoperating: Up to 12,000 m (40,000 ft.).

 

EMC Compliance - Meets or exceeds EN55011 Class A Radiated and Conducted Emissions; FCC47 CFR, Part 15, Subpart B, Class A.

Safety - EN61010-1; IEC61010-1.

I/O Interface

OM1420 OC-192 Clock Recovery Module -

Data In (Electrical SMA).

Clock Out (Electrical SMA).

 

Physical Characteristics

Shipping Weight with Packaging

Instrument/Module

kg

lbs.

OI1125

5.12

11.39

OI2125

5.49

12.22

OM1420

3.76

8.39

Ordering Information

OM1420

OC-192 Clock Recovery Module

Service

Opt. C3 - Calibration Service 3 Years

Opt. C5 - Calibration Service 5 Years

Opt. D1 - Calibration Data Report

Opt. D3 - Calibration Data Report 3 Years (with Option C3)

Opt. D5 - Calibration Data Report 5 Years (with Option C5)

Opt. R3 - Repair Service 3 Years

Opt. R5 - Repair Service 5 Years

Included Accessories - OM1420

071-1055-00 - User Reference: English only.

006-8018-01 - Important Documents Folder.

Certificate of Calibration: NIST, MIL-STD-45662A and ISO Calibration Certificate.

Placed inside "Important Documents Folder."

 

174-4699-00 - Cable, RF, Semi-rigid Jumper.

015-1022-01 - Terminator (2 each).

015-0561-00 - Electrical Cable, SMA (1 m long).