Download

Download Manuals, Datasheets, Software and more:

DOWNLOAD TYPE
MODEL or KEYWORD

Feedback

AWG5200 Series

Arbitrary Waveform GeneratorsDeclassification and Security

This document includes information that is necessary to clear or sanitize the product so it can be removed from a secured area, such as when returning the product for repair.


This manual applies to:

AWG5202, AWG5204, AWG5208

  • Manual Type: Declassification Manuals
  • Part Number: 077133800
  • Release Date:

By downloading, you agree to the terms and conditions of the Manuals Download Agreement.

Manuals Download Agreement

ATTENTION: please read the following terms and conditions carefully before downloading any documents from this website. By downloading manuals from Tektronix' website, you agree to the following terms and conditions:

Manuals for Products That Are Currently Supported:

Tektronix hereby grants permission and license to owners of Tektronix instruments to download and reproduce the manuals on this website for their own internal or personal use. Manuals for currently supported products may not be reproduced for distribution to others unless specifically authorized in writing by Tektronix, Inc.

A Tektronix manual may have been revised to reflect changes made to the product during its manufacturing life. Thus, different versions of a manual may exist for any given product. Care should be taken to ensure that one obtains the proper manual version for a specific product serial number.

Manuals for Products That Are No Longer Supported:

Tektronix cannot provide manuals for measurement products that are no longer eligible for long term support. Tektronix hereby grants permission and license for others to reproduce and distribute copies of any Tektronix measurement product manual, including user manuals, operator's manuals, service manuals, and the like, that (a) have a Tektronix Part Number and (b) are for a measurement product that is no longer supported by Tektronix.

A Tektronix manual may be revised to reflect changes made to the product during its manufacturing life. Thus, different versions of a manual may exist for any given product. Care should be taken to ensure that one obtains the proper manual version for a specific product serial number.

This permission and license does not apply to any manual or other publication that is still available from Tektronix, or to any manual or other publication for a video production product or a color printer product.

Disclaimer:

Tektronix does not warrant the accuracy or completeness of the information, text, graphics, schematics, parts lists, or other material contained within any measurement product manual or other publication that is not supplied by Tektronix or that is produced or distributed in accordance with the permission and license set forth above.

Tektronix may make changes to the content of this website or to its products at any time without notice.

Limitation of Liability:

TEKTRONIX SHALL NOT BE LIABLE FOR ANY DAMAGES WHATSOEVER (INCLUDING, WITHOUT LIMITATION, ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES, DAMAGES FOR LOSS OF PROFITS, BUSINESS INTERRUPTION, OR FOR INFRINGEMENT OF INTELLECTUAL PROPERTY) ARISING OUT OF THE USE OF ANY MEASUREMENT PRODUCT MANUAL OR OTHER PUBLICATION PRODUCED OR DISTRIBUTED IN ACCORDANCE WITH THE PERMISSION AND LICENSE SET FORTH ABOVE.

 

Read Online

Preface

This document helps customers with data security concerns to sanitize or remove memory devices from the Tektronix AWG5200 Series Arbitrary Waveform Generators.

All of these products have data storage (memory) devices and data output devices (USB ports and a LAN Ethernet connector). These instructions tell how to do the following:

  • Clear or sanitize the memory devices.

  • Clear or sanitize an instrument that is not functioning.

Reference

The procedures in this document are written to meet the requirements specified in:

  • NISPOM, DoD 5220.22–M, Chapter 8

  • ISFO Process Manual for Certification & Accreditation of Classified Systems under NISPOM

Products

The following Tektronix products are covered by this document:

  • AWG5202

  • AWG5204

  • AWG5208

Related documents

You can read more about your instrument in the following documents. These are available online at www.tektronix.com/downloads.

  • AWG5200 Series Arbitrary Waveform Generators Installation and Safety Instructions.

  • AWG5200 Arbitrary Waveform Generators Specifications and Performance Verification Technical Reference

Terms

The following terms may be used in this document:

  • Clear. This removes data on media/memory before reusing it in a secured area. All reusable memory is cleared to deny access to previously stored information by standard means of access.

  • Erase. This is equivalent to clear.

  • Instrument declassification. A term that refers to procedures that must be undertaken before an instrument can be removed from a secure environment. Declassification procedures include memory sanitization and memory removal, and sometimes both.

  • Media storage/data export device. Any of several devices that can be used to store or export data from the instrument, such as a USB port.

  • Nonvolatile memory. Data is retained when the instrument is powered off.

  • Power off. Some instruments have a “Standby” mode, in which power is still supplied to the instrument. For the purpose of clearing data, putting the instrument in Standby mode does not qualify as powering off. For these products, you will need to either press a rear-panel OFF switch or remove the power source from the instrument.

  • Remove. This is a physical means to clear the data by removing the memory device from the instrument. Instructions are available in the product Service Manual.

  • Sanitize. This eradicates the data from media/memory so that the data cannot be recovered by other means or technology. This is typically used when the device will be moved (temporarily or permanently) from a secured area to a non-secured area.

  • Scrub. This is equivalent to sanitize.

  • User accessible. User is able to directly retrieve the memory device contents.

  • User-modifiable. The user can write to the memory device during normal instrument operation, using the instrument interface or remote control.

  • Volatile memory. Data is lost when the instrument is powered off.

Clear and Sanitize Procedures

Memory devices

The following tables list the volatile and nonvolatile memory devices in the instrument and listed options. Detailed procedures to clear or sanitize these devices, if any, are shown following each table.

Terminology

The following terms are used in the tables in this section:

  • User data – Describes the type of information stored in the device. Refers to waveforms or other measurement data representing signals connected to the instrument by users.

  • User settings – Describes the type of information stored in the device. Refers to instrument settings that can be changed by the user.

  • Both – Describes the type of information stored in the device. It means that both user data and user settings are stored in the device.

  • None – Describes the type of information stored in the device. It means that neither user data nor user settings are stored in the device.

  • Directly – Describes how data is modified. It means that the user can modify the data.

  • Indirectly – Describes how data is modified. It means that the instrument system resources modify the data and that the user cannot modify the data.

Table 1. Volatile memory devices

Type and min. size

Function

Type of info stored (system/user)

Backed up by battery?

Method of modification

Data input method

Location

User accessible?

To clear/sanitize

SDRAM ≥4 GB (std)

PC system memory

Both

No

Directly

Written by processor system

Slot-PC board

Yes

Remove the power source from the instrument for at least 20 seconds.

SDRAM 4 Gbit

AWG playback memory

User

No

Indirectly

Firmware operations

AWG board

No

Remove the power source from the instrument for at least 20 seconds.

SRAM 64k x 16

USBTMC buffer

Both

No

Indirectly

Firmware operations

System board

No

Remove the power source from the instrument for at least 20 seconds.

Table 2. Nonvolatile memory devices

Type and min. size

Function

Type of user info stored

Method of modification

Data input method

Location

User accessible

To clear/sanitize

Flash, 1 Gbit

FPGA Image, Calibration Constants

None

Indirect

Firmware operations

AWG board

No

N/A1

Flash, 512 Mbit

FPGA Image, Instrument Model & Serial Number, Enabled Options

None

Indirect

Firmware operations

System board

No

N/A1

EEPROM 1 Mbit

USBTMC profile

None

Indirect

None

System board

No

N/A1

EEPROM 64 kbit

Calibration Constants

None

Indirect

Firmware operations

Clock board

No

N/A1

Flash, 1 Gbit

Calibration Constants

None

Indirect

Firmware operations

Marker board

No

N/A1

Flash, 1 Gbit

Calibration Constants

None

Indirect

Firmware operations

Output / DAC board

No

N/A1

Removable Hard Drive

Holds instrument operating system and application software. Holds all user-storable data such as waveforms, measurement results, and instrument settings.

User data, user settings

Indirect

Firmware operations, user input

Front panel

Yes

To clear, see footnote 2

To sanitize, see footnote 3

1 This device does not contain user data or settings. Clearing would disable instrument functionality.
2 To clear, reformat the hard drive using the procedure “Restore the OS and AWG application” in this document.
3 To sanitize, remove the hard drive. Store the removed hard drive in a secure area or destroy it.

Clear or sanitize a non-functional instrument

If your instrument is not functioning, proceed as follows.

  1. Remove the hard disk drive before returning the instrument for repair.

  2. Remove any attached USB flash drive before returning the instrument for repair.

Refer to your organization’s policies regarding storage or disposal of any removed items.

Clear or sanitize instrument

Use this procedure to clear the AWG waveform cache and last setup cache from your instrument. This procedure does not erase or change factory calibration constants.

  1. In the toolbar, click the Reset to Default Setup button.

  2. Close the AWG application.

  3. Open the AWG application.

Restore the OS and AWG application

Use this procedure to restore the operating system and the AWG application on your instrument to the original factory condition. This procedure does not erase or change factory calibration constants.

Note:This utility reformats the hard disk drive during the restore process. All user data will be removed. (The Acronis Recovery partition and the related data are not destroyed.)

The restore images remain, providing the ability to repeat the recovery process.

The Windows operating system provided is designed for this instrument's hardware and product software.

  1. Attach a keyboard to the instrument.

  2. Power on the instrument. During the boot-up process you will see the following message at the top of the screen:

    Starting Acronis Loader... press F5 for Acronis Startup Recovery Manager

  3. Repeatedly press the F5 key until the Acronis True Image Tool opens.

    There is a 15-second time period from when the message appears until the instrument proceeds with the normal instrument startup. If the instrument does not open the Acronis application, power off the instrument, then power on the instrument and try again.

  4. Within the Acronis TrueImage window, click Restore.

  5. In the Confirmation dialog box, click Yes to begin the restore the process, or No to exit.

  6. When finished, the AWG product software is the version shipped with your instrument. All upgrades or applications installed after your purchase will have to be reinstalled.

Media storage and data export devices

The following table lists the media storage and data export devices in the instrument and listed options. Detailed procedures to disable these devices, if any, are shown following the table.

Table 1. Media and data export devices

Type

Function

Method of modification

Data input method

Location

Process to disable

USB host port (supports removable USB flash drive)

User storage of reference waveforms, screen images, and instrument setups

Directly

User writable

USB host port on front and rear of instrument

The USB host ports cannot be disabled.

USB device port

Supports remote control and data transfer to a PC

Directly

Remote control via USBTMC and/or GPIB

Rear panel

The USB device port cannot be disabled.

LAN Ethernet connector

Supports remote control and data transfer to PC.

Directly

N/A

Rear panel

N/A

Help us improve our technical documentation. Provide feedback on our TekTalk documentation forum.